Our air purifier put to the test: safe air disinfection with proven efficacy
To make sure we can live up to our promises, our air purifiers are regularly tested by independent labs. The following studies prove that VIROBUSTER® technology is highly effective with 99.99% treatment rates for coronavirus (surrogates Phi6 and MS2), for example.
Our devices offer multiple benefits versus alternative products
VIROBUSTER® devices offer proven efficacy of >99.99% against SARS-CoV2 surrogates (Phi6 and MS2 bacteriophages) in just one cycle.
The combination of slow intake and a high output speed guarantees a reduction in microbial counts for the whole room - in just a few minutes.
The pedestal offers stability, and the fan it contains is extremely quiet given its air flow capacity. It can therefore be used long term, for example in offices, hospital rooms and bedrooms.
Our devices work solely on the basis of UV-C. This means there are no filters or hazardous additional technologies such as plasma (ozone) or ionisation, making it an emission-free solution that is safe for users and the environment.
As there are no filters that would require regular changing, maintenance is only required every 2-3 years. Its low maintenance costs make STERIBASE® the perfect choice.
Device efficacy
Result: >99.99 % (>4 LOG)
The goal of the study was to analyse how well the STERIBASE® Plus system inactivates coronavirus surrogates.
Two coronavirus surrogates were used: Phi6 and MS2 bacteriophages. Phi 6: Cystoviridae, lipid-enveloped virus, dsRNA, MW RNA approx. 13.5 kb, diameter 60-100 nm MS2: Leviviridae, no envelope, ssRNA, MW RNA approx. 4 kb, diameter 26 nm
Result: This study proved UVPE to be more effective than traditional UV-C systems by >3 LOG
The goal of the experiment was to show that traditional filters do not work against viruses and that viruses survive in air handling systems. According to studies, UV-C systems are an effective alternative.
Result: >99.9999 % (>6 LOG)
The goal of the study was to analyse how well the STERITUBE® inactivates influenza surrogates.
This used: Bacteriophage MS2 (strain DSM13767), host bacteria: E. coli TOP10F’ – Infection via F family pili: Leviviridae Structure/size: naked; diameter 250 A (icosahedral shape); diameter 25-27 nm
Genome: 1s-RNA; 4 genes on a 3569 nucleotide genome
Proteins: 180 envelope protein and 1 adsorption protein copies
Result: 3.6 log (99.98 %) reduction by VIROBUSTER® versus traditional air handling systems
Viruses (coronavirus surrogate: bacteriophage MS2), which are introduced into an air handling system in aerosolisation studies, are still present in an infectious form in the supply airflow up to four hours later. The F5/F7 filter elements used in air handling systems are not able to retain viruses sufficiently. The integration of UV-C modules in the airflow can in part reduce viruses to below the diagnostic threshold.
Space efficacy
Result: STERIBASE® is the only powerful solution in terms of space efficacy.
The series of tests is used to verify the efficacy of individual devices in terms of a reduction in microbial count. The criteria measured were “air recirculation” (measurements in a hermetically sealed room with several cycles) and “single cycle”. Furthermore, as part of the series of tests, the aspiration capacity and air circulation of the test devices was also measured.
Result: Across the area as a whole, pathogens were reduced by 67% and mould spores by 84%.
The objective of this prospective, multi-centre user observation was to establish the mechanism of action of STERIBASE® with regard to the elimination of active bacteria and mould in room air under practical conditions. VIROBUSTER®’s UVPE technology contributes to increased air purity, even for UV-stable pathogens. This user observation thus supports the importance of UV-C technology as a valuable tool for reducing microbial counts in room air.
Safety & Sustainability
Result: Zero emissions In this study, 12 testers assessed the odour emissions/room air quality of the VIROBUSTER® STERIBASE® 300 Plus.
All testers were trained and met the DIN EN 13725 selection criteria with regard to the reference substance n-Butanol. Samples were taken from the outlet of the VIROBUSTER® device and tested for three parameters: odour concentration (as per DIN EN 13725), intensity and hedonics (rated as per VDI 3882).
Result: No presence of VOCs This study tested whether using the VIROBUSTER® system results in a change in the volatile organic compounds (VOCs) in room air, and whether additional VOCs are found as a result of the system. VOC is an umbrella term for carbon-containing (organic) substances that evaporate easily (volatile) or are already gaseous at low temperatures (e.g. room temperature).
Let us find the right solution for you!
We look forward to hearing from you – call us on
+49 (0) 2244/8440-300 or email us.
The VIROBUSTER® Service
From providing information on the most efficient air purification concept to installation on your premises.
Advice
Are you interested in UV-C air purification, would like to switch or don’t know which system is right for you? Ask us - we’ll be happy to advise.
Planning
Do you have specific requirements or your own ideas? Contact us to plan your individual project and make your company future-proof in terms of UV-C air purification.
Installation
We also handle delivery and installation, so that you can focus on what’s important for you.
Service
We’re here for you after installation and commissioning. Do you need replacement parts, or information on your devices and UV-C air purification? Get in touch!